ECS-180B temperature controller could be used in the middle and low-temperature medicine cabinet, kitchen cabinet, supermarket split cabinet, air curtain cabinet, island counter, wine cabinet, etc.
Four-way sensor input: temperature probe sensor, condenser probe sensor, evaporator probe sensor, door switch.
Four-way control output: refrigeration, defrosting, fan, lighting/alarm relay.
Function
Model | Control Output | |||
Cooling | Defrosting | Fan | Lighting / Alarming | |
ECS-180B (℃/℉) |
5A | 10A | 10A | 5A |
Signal Input | ||||
Temperature Sensor | Condenser Sensor | Evaporator Defrost Sensor | Door Switch | |
√ | √ | √ | √ |
Parameter
Model | ECS-180B |
Operating Voltage | 220VAC±10%; 50/60Hz |
Overall Power Consumption | <3W |
Temperature Measurement Range | -50℃-90℃ (-58℉-194℉) |
Temperature Control Range | -50℃-85℃ (-58℉-185℉) |
Temperature Measurement Accuracy | ±1℃(-40℃~50℃ ), ±2℃(51℃~70℃) |
Display Resolution | 0.1℃/1℉ |
Product Size | 78.5×34.5×82(mm) |
Mounting Dimension | 71×29 (mm) |
Input Sensor | Temperature Sensor, Evaporator Sensor, Condenser Sensor, Door Switch |
Rated Current of Output Relay | 5A/250VAC (Cooling, Lighting/Alarm) |
Rated Current of Output Relay | 10A/250VAC (Defrosting, Fan) |
Front Panel Waterproof Level | IP65 |
Feature
- The large panel of color digital tube, work status symbol display, the temperature display resolution is 0.1, the front panel waterproof level lP65.
- lt has a temperature sensor self-test function, and once test the failures, it has multiple protection and alarm methods. lt has the function of one-key recovery, and the rear adopts the plug-in connection method to effectively simplify processing for equipment manufacturers.
- The temperature measuring unit could switch between Celsius and Fahrenheit.
- With the function of Synchronous defrost switch signal detection, and it could form the network of real-time clock Synchronous defrost.
- Cabinet temperature over-limit alarm has two modes: absolute value and relative value.
- Light/external alarm relay could be selected by the software, and then select the function of external alarm relay, it could connect the remote alarm bell.
- If selected to install a standby power supply access unit, which could realize the function of off-power detection and alarm.
- With the complete control logic of hot-gas defrost start without the pressure difference in the refrigerant pipe, to prevent starting with the pressure, for the purpose of a longer compressor life.
Elitech ECS-180B Four-way Outputs Temperature Controller User Manual